On the Double-Step PIV Algorithm of Wall-Bounded Flows
DOI:
https://doi.org/10.4208/aamm.2018.s11Keywords:
PIV, hypersonic boundary layer, window-correlation algorithm.Abstract
Double-step interrogation schemes with decreasing window size are investigated. Particle image pairs are created by Monte Carlo methods based on a simulated hypersonic transitional boundary layer flow. Two types of initial-step interpolation, with and without non-slip conditions at the wall (so-called CSIN and CSI), are respectively investigated. It can be concluded that the non-slip condition is very important to the multi-grid interrogation scheme. CSIN has a good agreement with the preset results but CSI does not.\u00a0 The error level of CSI near the wall is nearly 5 times that of CSIN.